10-OPERATION
A high percentage of moisture causes condensation in the smoke duct, thereby causing an alteration to the draught and
generating smoke and considerable soot deposits in the rebox, on the glass of the door and on the product, with the
subsequent risk of this catching re. It also leads to a much lower overall eciency.
The use of humid or treated wood releases a greater amount of smoke than usual, which could dirty the glass more quickly.
Poor chimney performance can also compromise the cleanliness of the glass, as the smoke remains in the combustion chamber
longer than usual.
Do not use treated fuels (painted or lacquered wood) or non-compliant fuels (plastic or derivatives), which could
release toxic substances or pollutants.
Do not burn waste.
The gases produced by combustion of unsuitable fuel could damage the product and pollute and compromise your
health.
USING THE STOVE
OPENING/CLOSING THE DOOR
The product is equipped with an automatic door closing system. Using the leather glove supplied, pull the door towards you and the door
opens. To close it simply let go and the door will close automatically.
NOTE: for the door closing system to work properly, the product must be installed according to the feet adjustment guidelines in Chap. 4.
FUEL LOADING
To load the fuel, simply open the door by pulling the handle and pulling the door towards you.
The metal parts and the glass become very hot during operation, therefore use adequate protection.
The door to the combustion chamber must remain closed during combustion.
It is forbidden to load larger quantities of fuel than those specied in the technical datasheets of each individual
product.
An excessive amount of fuel in the combustion chamber could damage and deform the rebox and the structure of
the product.
The company cannot be held liable for any damage caused by fuel overloads or if non-compliant fuel is used.
COMBUSTION CONTROL
Combustion adjustment and therefore the combustion air intake is controlled via a single control knob.
The inlet air is either:
PRIMARY AIR:
the primary air is pre-set and is mainly delivered to help the ignition process of the product.
SECONDARY AIR:
emission of secondary air is predetermined, and is used for the partial cleaning of the glass and allows the completion of the combustion
process. Thanks to this process, heating performance and eciency of the product are enhanced.