8 - ELECTRICAL CONNECTION
OPERATING MODE
The operating mode for hydro stoves is only AUTOMATIC (there is no manual operating mode available). The modulation of the ame is
controlled according to the "System conguration" by the room temperature probe located at the back of the appliance (see img.), by the
external thermostat, by the temperature of the water in the boiler, or by the NTC probes.
ELECTRICAL CONNECTIONS
TERMINAL BLOCK CONTACTS
POS.1-2 EXTERNAL THERMOSTAT/PUFFER THERMOSTAT POS.8 NEUTRAL THREE-WAY VALVE
POS.3-4 PUFFER/BOILER PROBE POS.9 THREE-WAY VALVE PHASE (heating)
POS.5 EARTHING
POS.6-7 AUXILIARY STOVE