36
7982
80
A2
E
C
A1
C
A2
E
A1
559
172
7 - HYDRAULIC CONNECTION
HYDRAULIC CONNECTION
C
SAFETY VALVE 3 bar – 1/2” F
A1
Heating water supply 3/4”M
E
SYSTEM EMPTYING 1/2”F
A2
HEATING WATER RETURN 3/4” M
IMPORTANT!!!
CLEAN THE ENTIRE SYSTEM BEFORE CONNECTING THE STOVE, IN ORDER TO REMOVE ALL RESIDUE AND DEPOSITS.
Always install shutters in the system leading to the stove so as to disconnect it from the hydraulic system in order to
carry out routine and/or special maintenance.
Connect the stove using exible pipes.
Comments to this Manuals