11-PROBLEMS/CAUSES/SOLUTIONS
ANOMALIES RELATED TO THE PLUMBING SYSTEM
ANOMALY POSSIBLE CAUSES SOLUTIONS
No increase in temperature with
stove in operation.
Incorrect combustion setting. Check recipe.
Boiler/system dirty. Check and clean the boiler.
Product power insucient. Check that the stove is properly sized for
the requirements of the system.
Poor pellets quality. Use of MCZ pellets.
Condensation in boiler. Incorrect temperature setting. Set the stove to a higher temperature.
Insucient fuel consumption. Check recipe.
Radiators cold in winter. Room thermostat (local or remote) set
too low. If remote thermostat, check if it
is defective.
Set the room thermostat at a higher
temperature, if needed replace it (if
remote).
Circulator does not run because blocked. Free up the circulator by removing the plug
and turning the shaft with a screwdriver.
Circulator does not run. Check the electrical connections of the
circulator; replace if necessary.
Radiators have air in them. Bleed the radiators.
Hot water is not provided. Circulator (pump) blocked. Free the circulator (pump).