Mcz Vivo 90 Pellet Comfort Air User Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 64
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
A
B
C
A
9
3-INSTALLATION
Technical Dept. - All rights reserved - Reproduction is prohibited
FOREWORD
The installation position must be chosen according to the room, to the smoke extraction system, to the chimney ue. Check with local
authorities whether there are any restrictive regulations in force regarding the combustion air inlet, the smoke outlet system, the
ue or the chimney cap. The manufacturer declines all responsibility in the event of installations that do not comply with the laws in
force, incorrect room air exchange, electrical connection non-compliant with the standards and inappropriate use of the appliance. The
installation must be carried out by a qualied technician, who must issue a declaration of conformity of the system to the purchaser and
will assume full responsibility for nal installation and consequent good operation of the product.
In particular one must ensure that:
• there is a suitable combustion air inlet and smoke outlet in compliance with the type of product installed
• other stoves or devices installed do not cause depression in the room where the product is installed (for sealed appliances only, a
maximum of 15 Pa of depression in the room is allowed)
• when the product is switched on there is no reux of smoke in the room
• fumes extraction takes place in total safety (sizing, smoke seal, distances from ammable materials..).
We especially recommend to check the data tags of the ue for the safety distances that must be observed in presence
of combustible materials and the type of insulating material to be used. These indications must be followed strictly to
prevent serious harm to people and the integrity of the home. The installation of the appliance must ensure easy access to
clean the appliance itself, the smoke outlet pipes and the ue. It is forbidden to install the stove in rooms with a re hazard.
Installation in studio ats, bedrooms and bathrooms is only allowed with sealed or closed appliances equipped with
suitable combustion air ducting directly outside. Always maintain adequate distance and protection in order to prevent
the product from coming into contact with water.
In the event there are several appliances installed, the external air inlet must be sized accordingly.
MINIMUM DISTANCES
It is recommended to install the stove detached from any walls and/or furniture, with a minimum clearance to allow eective aeration
of the appliance and a good distribution of heat in the room. Observe the distances from ammable or heat-sensitive objects (sofas,
furniture, wood panelling, etc..) as specied. The front distance from inammable materials must be at least 80 cm.
If particularly delicate objects are present, such as furniture, curtains or sofas, increase the stove clearance accordingly.
If the oor is made of wood, it is recommended to t a oor protection sheet in compliance with the Standards in
force in the country of installation.
VIVO 90 PELLET
Non-ammable walls Flammable walls
A = 5 cm
B = 5 cm
C = 5 cm
A = 5 cm
B = 5 cm
C = 5 cm
If the oor is made of combustible material, it is recommended to use protection made of non-combustible material (steel, glass...) that
also protects the front from falling combusted material during cleaning operations.
The appliance must be installed on a oor with adequate load capacity.
If the existing construction does not meet this requirement, one must take appropriate measures (for example a load distribution plate).
Page view 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 63 64

Comments to this Manuals

No comments